DO-160, Environmental Conditions and Test Procedures for Airborne Equipment, published by RTCA (Radio Technical Commission for Aeronautics), is the international standard that defines environmental test conditions and applicable test procedures and criteria for avionic equipment to determine their performance …

What is an RTCA DO?

RTCA DO-160G provides standard procedures and environmental test criteria for testing airborne equipment for the entire spectrum of aircraft from light general aviation aircraft and helicopters through the “jumbo jets” and SST categories of aircraft. The document includes 26 Sections and three Appendices.

Is STD 160 mil?

MIL-STD-810. DO-160 test procedures are specifically tailored to assess the performance and durability characteristics of equipment intended to function and survive in challenging or extreme aircraft environments. It is used primarily by the aviation and aerospace industries.

Does temperature of 160 have variation?

The purpose of RTCA DO-160 temperature variation testing is to determine the performance characteristics of equipment operating between high and low operating temperature extremes. It is important to note that this temperature testing is just temperature testing.

Do 160g Do section 15?

The RTCA/DO-160 Section 15 measures the magnetic effect of the equipment and its main goal is to determine the closest distance to compasses or compass sensors (flux gates) at which that unit is allowed to be installed. The deflection of the compass is equal to 1˚ when measured >0.0 m to ≤0.3 m to the equipment.

Do 160g Do section 16?

RTCA/DO-160 Section 16 tests verify whether the equipment will negatively affect the aircraft power system that would be harmful or degrade performance in other equipment. These tests cover both susceptibility (surge, dropout, frequency transients, etc.)

Does 160g Do section 22?

RTCA/DO-160 Section 22 offers test procedures to determine whether the EUT can operate as specified during and/or after various lightning induced transient waveforms are injected into connector pins, interconnecting cables, and power leads using pin injection, and/or cable bundle tests.

Does 160 have indirect lightning?

DO-160 lightning induced transient susceptibility or indirect lightning is typically the most severe transient test in all of DO-160. However, cable bundle testing requires the unit to operate through the lightning strike making the unit more susceptible to failure.

What is pin injection?

Pin injection uses a fixed energy level, calibrated before the test and applies it to each pin of your unit. The VOC represents an open circuit voltage and the ISC represents a short circuit current. The waveform generator’s amplitude is increased until an open circuit voltage at the required level is achieved.

Does 160 voltage spike?

The RTCA DO-160 voltage spike test determines whether equipment can withstand the effects of voltage spikes. These spikes arrive at the equipment on its power leads. This can occur via either ac or dc power. The adverse effects voltage spikes can have on equipment are numerous and range in degree of severity.